Omron — Symbols Glossary

Symbols
Glossary
5.1.1 / Manufacturer
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the medical device manufacturer
5.1.2 / Authorized representative in the European Community
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the authorized representative in the European union. Symbol is accompanied by the name and address of the authorized representative adjacent to the symbol
5.1.3 / Date of Manufacture
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the date when the medical device was manufactured
5.1.4 / Use-by-date
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the date after which the medical device is not to be used
5.1.5 / Batch code
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the manufacturer’s batch code or lot can be identified
5.1.6 / Catalogue number
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the manufacturer’s catalogue number so the medical device can be identified
5.1.7 / Serial number
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the manufacturer’s serial number so that a specific medical device can be identified
5.2.8 / Do not use if package is damaged
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates a medical device that should not be used if the package has been damaged or opened
5.3.1 / Fragile, handle with care
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates a medical device that can be broken or damaged if not handled carefully
5.3.4 / Keep dry
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates a medical device that needs to be protected from moisture
5.3.5 / Lower limit of temperature
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the lower limit of temperature to which the medical device can be safely exposed
5.3.6 / Upper limit of temperature
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the upper limit of temperature to which the medical device can be safely exposed
5.3.7 / Temperature limit
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the temperature limits to which the medial device can be safely exposed
5.3.8 / Humidity limitation
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the range of humidity to which the medical device can be safely exposed
5.3.9 / Atmospheric pressure limitation
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the range of atmospheric pressure to which the medical device can be safely exposed
5.4.3 / Consult instructions for use
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the need for the user to consult the instructions for use
5.4.4 / Caution
Standard No. / Standard Title : ISO 15223-1 / Medical devices-Symbols to be used with medical device labels, labelling and information to be supplied

Symbol Meaning : Indicates the need for the user to consult the instructions for use for important information such as warnings and cautions
5333 / Type BF applied part
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Identifies a type BF applied part complying with IEC 60601-1
5840 / Type B applied part
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Identifies a type B applied part complying with IEC 60601-1
5172 / Class II equipment
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Identifies equipment meeting the safety requirements specified for Class II equipment according to IEC 61140
5926 / Polarity of d. c. power connector
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Identifies the positive and negative connections of a d. c. power supply
5957 / For indoor use only
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Identifies electrical equipment designed for indoor use
5032 / Alternating Current
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Indicates that the equipment is suitable for alternating current only; to identify relevant terminals
5031 / Direct current
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Indicates that the equipment is suitable for direct current only; to identify relevant terminals
5140 / Non-ionizing electromagnetic radiation
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Indicates generally elevated, potentially hazardous, levels of non-ionizing radiation, or to indicate equipment or systems e.g. that intentionally apply RF electro-magnetic for diagnosis or treatment
5009 / Stand-by
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Identifies the switch or switch position by means of which part of the equipment is switched on in order to bring it into the standby condition
5016 / Fuse
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Identifies fuse boxes or their locations
5008 / “OFF”
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Indicates disconnection from the mains, at least for mains switches or their positions, and all those cases where safety is involved
5007 / “ON”

Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Indicates connection to the mains, at least for mains switches or their positions, and all those cases where safety is involved
5104 / Start; start of action
Standard No. / Standard Title : IEC 60417 / Graphical symbols for use on equipment

Symbol Meaning : Identifies the start button
M002 / Refer to instruction manual / booklet
Standard No. / Standard Title : ISO 7010 / Graphical symbols — Safety colours and safety signs — Registered safety signs

Symbol Meaning : Indicates that the instruction manual / booklet must be read
P007 / No access for people with active implanted cardiac devices
Standard No. / Standard Title : ISO 7010 / Graphical symbols — Safety colours and safety signs — Registered safety signs

Symbol Meaning : Indicates that people with active implanted cardiac devices are prohibited from entering a designated area
0623 / This way up
Standard No. / Standard Title : ISO 7000 / Graphical symbols for use on equipment

Symbol Meaning : Indicates the correct upright position of a package
IP20
Standard No. / Standard Title : IEC 60529 / Degrees of protection provided by enclosures (IP Code)

Symbol Meaning : Protected against solid objects over 12.5mm (e.g., a finger) and no protection against liquids
IP21
Standard No. / Standard Title : IEC 60529 / Degrees of protection provided by enclosures (IP Code)

Symbol Meaning : Protected against solid objects over 12.5mm (e.g., a finger) and protected against vertically falling drops of water or condensation

IP22

Standard No. / Standard Title : IEC 60529 / Degrees of protection provided by enclosures (IP Code)

Symbol Meaning : Protected against solid objects over 12.5mm (e.g., a finger) and protected against falling drops of water, if the case is disposed at any angle up to 15 degrees from vertical
IP54
Standard No. / Standard Title : IEC 60529 / Degrees of protection provided by enclosures (IP Code)

Symbol Meaning : Protected from limited dust ingress. Protected from water spray from any direction, limited ingress protection
IP55
Standard No. / Standard Title : IEC 60529 / Degrees of protection provided by enclosures (IP Code)

Symbol Meaning : Protected from limited dust ingress. Protected from water jets from any direction, limited ingress protection
Prescription Device
Standard No. / Standard Title : 21 CFR 801.109 / Prescription Devices

Symbol Meaning : Indicates that the product is a medical device and Federal Law (USA) restricts this device to sale by or on the order of a physician
CE Marking
Standard No. / Standard Title : Medical Devices Directive 93/42/EEC

Symbol Meaning : CE marking indicates that a product complies with applicable European Union regulations
Crossed out wheelie bin
Standard No. / Standard Title : BS EN 50419, Marking of electrical and electronic equipment in accordance with article 11(2) of Directive 2002/96/EC (WEEE)

Symbol Meaning : Indicates a product should not be disposed of in a landfill; the black bar indicates that the equipment was manufactured after 2005
FCC Marking
Standard No. / Standard Title : Federal Communications Commission

Symbol Meaning : FCC marking indicates the electronic device, which sold in the United States, is certified and the electromagnetic interference from the device is under the limits that are approved by Federal Communications Commission
Cuff Positioning
Standard No. / Standard Title : N/A

Symbol Meaning : Indicates the correct positioning for the monitor on the wrist
Cuff Positioning
Standard No. / Standard Title : N/A

Symbol Meaning : Indicates the correct positioning for the monitor on the wrist
Artery Marks
Standard No. / Standard Title : N/A

Symbol Meaning : Types of marks used to indicate the correct positioning of the artery for the upper arm
Cuff Positioning
Standard No. / Standard Title : N/A

Symbol Meaning : Indicator on the cuff for left upper arm
Cuff Indicator
Standard No. / Standard Title : N/A

Symbol Meaning : Range pointer and brachial artery alignment positioning indicator on the cuff
Cuff Identifier
Standard No. / Standard Title : N/A

Symbol Meaning : Identifies the type of cuff that is compatible with the blood pressure monitor
Cuff Identifier
Standard No. / Standard Title : N/A

Symbol Meaning : Identifies the type of cuff that is compatible with the blood pressure monitor
Arm Circumference Range
Standard No. / Standard Title : N/A

Symbol Meaning : Indicates the range of arm circumferences to help with selection of the correct cuff size
Warnings
Standard No. / Standard Title : N/A

Symbol Meaning : Various warning symbols to indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury
Marking for the position of the replaceable air tube
Standard No. / Standard Title : N/A

Symbol Meaning : Indicates the position to insert the air tube